Sievers M9 Portable TOC Analyzer
The lightweight, compact design of the Sievers M9 Portable Analyzer gives you the option for TOC analysis at various locations- at-line, online, or in the lab. It offers the same accuracy and compliance as the lab model, but it can be installed online for continuous measurement or carried to any location in the water system for troubleshooting. The M9 Portable has options for simultaneous Stage 1 conductivity testing and for four-second analysis with Turbo mode for fast response applications. For the pharmaceutical industry, Sievers Validation Support Packages (VSPs) help you navigate the M9 validation process and enable a more efficient instrument implementation. The new Sievers VSP for software is written specifically to address Data Integrity and 21 CFR Part 11 by validating Sievers DataPro2 software.
M9 Portable Specifications
Operating Specifications* |
|
---|---|
Range | 0.03 ppb to 50 ppm |
Precision | < 1% RSD |
Accuracy | ± 2% or ± 0.5 ppb, whichever is greater |
Display Readout | 3 significant digits |
Sample Type | On-line continuous, Autosampler or discrete grab sample |
Calibration | Typically stable for 12 months |
Analysis Time | 2 minutes (4 seconds with the optional Turbo mode) |
Sample Temperature** | 5–95 °C (41–203 °F) |
Ambient Temperature | 5–40 °C (41–104 °F) |
Sample Pressure | 100 psig |
On-Line Flow Rate | >50 mL/min (for on-line mode) |
Instrument Sample Flow Rate |
0.5 mL/min |
Analyzer Specifications |
|
Outputs | 4-20 mA outputs (3); alarm outputs (4); binary input (1); USB device port (1); USB host ports (2); Modbus TCP/IP |
Display | 7″ WVGA 800X480 pixel, Color LCD with touch-screen |
Power | 100 – 240 V~, 50 -60 Hz, 100 VA |
Fuses | Replace with same type and size fuse: T 1.6 A 250 VAC Fuse (Slow Blow), size 5 X 20 mm appliance inlet |
Dimensions | H: 39.5 cm (15.4 in); W: 22.9 cm (9.0 in); D: 46.4 cm (18.3 in) |
Weight | 9.4 kg (20.8 lb) |
Enclosure Rating | IP-21 |
Safety Certifications | ETL, CE (see Declaration of Conformity) |
Sample Conductivity (Optional) |
|
Raw Conductivity Range | 0.01 to 2,000 μS/cm |
Conductivity Accuracy | ±0.005 μS/cm or ±1%.whichever is greater |
Pollution Degree | <0.25% RSD |
Environment |
|
Maximum Relative Humidity | 0 – 95%, non-condensing |
Maximum Altitude | 3,000 m (9.800 ft) |
Pollution Degree | 2 |
The UV lamp inside this product contains mercury and must be recycled or disposed of in accordance with local, state, and federal laws. | |
* Stated analytical performance is achievable under controlled laboratory conditions that minimize operator and standards errors. **Sample temperature above 60 °C requires optional PVDF iOS |
M9 Portable Turbo Specifications
Operating Specifications* |
|
---|---|
Range | 0.20 ppb to 10 ppm |
Precision | 2% RSD |
Accuracy | ±10% or ±10 ppb whichever is greater |
Display Readout | 3 significant digits |
Sample Type | On-line, Grab, Autosampler |
Calibration | Typically stable for 12 months |
Analysis Time | 4 seconds |
Response Time | 3.25 minutes |
Sample Temperature | 5–95 °C (41–203 °F) |
Ambient Temperature | 10–40 °C (50–104 °F) |
Sample Pressure** | 100 psi |
Sample Flow Rate | 30–300 mL/min (for on-line mode) |
Instrument Sample Flow Rate |
1.1 mL/min |
Analyzer Specifications |
|
Outputs | 4-20 mA outputs (3); alarm outputs (4); binary input (1); USB device port (1), USB host ports (2); Ethernet (1) |
Display | 7” WVGA 800×480 pixel, Color LCD w/touch-screen |
Power | Universal Power Supply: 100–240 ± 10% VAC, 50 W, 50/60 Hz |
Dimensions | H: 39.5 cm (15.4); W: 22.9 cm (9.0 in); D: 46.4 cm (18.3 in) |
Weight | 9.4 kg (20.8 lbs) |
Safety Certifications | ETL, CE |
Consumables |
|
UV Lamp | 6 months |
Acid Reagent | As needed, typically 6 months |
Oxidizer Reagent | As needed, typically 3-month stability |
M9 Portable Options & Accessories
- Sievers Autosampler: 63 or 120 sample-position capacity
- DataPro2 Software: Custom sample protocols; automated calibration and validation protocols
- DataGuard Software: Full compliance support for 21 CFR Part 11 and Annex 11
- Inorganic Carbon Remover (ICR): Improves TOC accuracy for samples with high inorganic carbon levels
- Sample Conductivity: Measure and report sample conductivity
- Turbo Mode: Provides four-second analysis time
Sievers M9 Portable for Maintenance and Control of Pharmaceutical Water Systems
The Sievers M9 Portable makes monitoring and troubleshooting pharmaceutical water systems easier. Whether showing the rinseout of a water system after sanitization or detecting heat exchanger leaks, the M9 Portable can be an effective utility tool for properly maintaining pharmaceutical water systems.
Cleaning Validation (Lab, At-Line, and On-Line) with Sievers M9 TOC Analyzers
Not sure which analyzer you need for cleaning validation? This document compares the M9 Lab, Portable, and On-Line to help you select the right analyzer for your application.
21 CFR Part 11 with the Sievers M9 and DataPro2 Software
Sievers M9 Analyzers are compliant with 21 CFR Part 11. Our DataPro2 and Dataguard software are designed for the pharmaceutical industry to offer complete solutions for electronic signatures and audit trails.